INNO3D RTX 5090 D Night X3 AIO Liquid Cooler, 360 mm | Bykski B-FRD-ICH5090DX3

Bykski · B-FRD-ICH5090DX3

360 mm GPU liquid cooler for the INNO3D RTX 5090 D Night X3

The Bykski B-FRD-ICH5090DX3 is a 360 mm all-in-one GPU liquid cooler for the 32 GB INNO3D GeForce RTX 5090 D Night X3 and the specific INNO3D and MSI boards listed below. The full-cover block takes heat from the GPU, memory, and power stages. An inline pump circulates coolant to a fan-cooled radiator mounted in the case.

Fits
INNO3D RTX 5090 D Night X3 (32 GB)
Radiator
360 mm
Cold plate
Copper
Configurations
Single or dual GPU

Compatibility

Bykski lists these board models:

  • ✓INNO3D GeForce RTX 5090 D Night X3 (32 GB, N509D3-32D7-17593928)
  • ✓INNO3D GeForce RTX 5090 iCHILL Frostbite (C50903-32D7X-1759FB)
  • ✓INNO3D GeForce RTX 5090 iCHILL X3 (C50903-32D7X-175967H)
  • ✓INNO3D GeForce RTX 5090 X3 (N50903-32D7-17593928)
  • ✓MSI GeForce RTX 5090 D 32G VENTUS 3X OC
  • ✓MSI GeForce RTX 5090 D 32G VENTUS 3X

Verify your exact card model and PCB layout against Bykski's compatibility information before ordering.

INNO3D GeForce RTX 5090 D Night X3 PCB with the stock cooler removed.

Design Highlights

A case-mounted radiator with three fans

Both configurations include three 120 mm radiator fans. The pump sits in the tubing between the radiator and the GPU block.

GPU block dimensions in millimeters (manufacturer drawing).

Full-cover block with a copper cold plate

The copper cold plate draws heat from the GPU, memory, and power stages. Its 0.3 mm jet microchannels increase the surface area in contact with coolant.

Example top-mounted radiator and tubing route (manufacturer drawing).

Room to route the pump and tubing

Bykski shows the radiator at the top of the case and the tubing routed down to the card. Check that your case has room for the inline pump and tubing along that route.

Key Specifications

ModelB-FRD-ICH5090DX3-360 (single GPU)
B-FRD-ICH5090DX3-360-H (dual GPU)
CoverageGPU core, memory, and power stages
Cold plateCopper
GPU block size233.66 × 129.94 × 16.85 mm (manufacturer drawing)
Jet microchannels0.3 mm, up to 44 channels, 13,453.91 mm² of coolant contact area
RadiatorOne 360 mm radiator per kit
Radiator length396 mm, end to end (both kits)
Radiator and fan thickness63 mm with fans fitted (38 mm radiator + 25 mm fans), for both -360 and -360-H
Fans3 × 120 mm, 25 mm thick, included with either kit. Standard kit fans are rated at 3,000 RPM (±10%).
Pump (standard 360)Inline, 7,000 RPM, 450 L/h, 7 m head
Tubing (standard 360)Braided tubing

Bykski’s standard 360 drawing labels the radiator at 396 mm end to end and 63 mm thick with fans fitted. The 70 mm, 360.93 mm, and 480 mm markings show vertical distances in the illustration.

Which Version Do I Need?

Pick the option for the number of graphics cards you need to cool. Allow 63 mm at the case mount for either kit with fans fitted.

B-FRD-ICH5090DX3-360
Choose 360mm for one compatible card. It includes one GPU block and one dedicated backplate.
B-FRD-ICH5090DX3-360-H
The 360mm Thick row (Dual Graphics Cards) option includes two GPU blocks and two dedicated backplates with one shared 360 mm radiator. Send customer service the full model and PCB layout of each card for a fit check before ordering.

Check the full model on the card label. The RTX 5090 D v2 carries 24 GB, while the original RTX 5090 D carries 32 GB. INNO3D also lists iCHILL Frostbite and iCHILL Frostbite Pro as separate models.

What's in the Box

360 mm GPU AIO kit

Both kits come with the pump and tubing connected and coolant already filled. Each kit includes one 360 mm radiator, three 120 mm fans, and thermal pads. The single-GPU kit includes one GPU block and one dedicated backplate. The dual-GPU kit includes two GPU blocks and two dedicated backplates.

Thermal paste is not included (it cannot be shipped by air). Please use your own GPU thermal paste during installation.

Installation & Use

1
Remove the card's stock cooler and clean off the old thermal material.
2
Cut and place the thermal pads at the memory and power-stage contact areas on your board. Apply thermal paste to the GPU die.
3
Align the block standoffs with the PCB screw holes. Fit the block and secure the included backplate. If the holes do not align, stop and have a technician check the fit.
4
Mount the radiator and fans. The manufacturer illustrates a top mount. Leave room to route the pump and tubing between the card and radiator.
5
Verify the pump and fan connections for your kit and motherboard before powering the system.

Use a case with a 360 mm radiator mount. For either kit, allow 396 mm for the radiator length and 63 mm of thickness with the fans fitted. Check clearance for the pump and tubing route. Check which thermal pads and mounting hardware your board needs before installation.

FAQ

Where is the pump mounted?

The pump sits inline between the GPU block and radiator. Allow space for it when planning the tubing route.

Will either 360 mm kit fit my case?

Both kits need a 360 mm radiator mount with room for 396 mm of radiator length and 63 mm of thickness with the fans fitted (38 mm radiator + 25 mm fans). Leave room for the tubing and inline pump.

What does the -H suffix mean on this model?

It identifies the dual-GPU kit. It includes two GPU blocks and two dedicated backplates, and both blocks share one 360 mm radiator.

How do I tell the two MSI VENTUS models apart?

Check the full name on the card label. The compatibility list has separate entries for the MSI GeForce RTX 5090 D 32G VENTUS 3X OC and the MSI GeForce RTX 5090 D 32G VENTUS 3X.

Can I replace the stock cooler on my INNO3D RTX 5090 D Night X3?

Yes. The AIO replaces the stock air cooler with a full-cover block for the GPU, memory, and power stages. Check the exact card model and PCB layout before ordering.

Notes
  • For any questions, please contact customer service.