Leadtek RTX A6000, NVIDIA A40 & A10 Water Block with Active Backplate — Bykski N-RTXA6000-TC-V3

Bykski · N-RTXA6000-TC-V3

Full-cover GPU water block with a liquid-cooled backplate

The Bykski N-RTXA6000-TC-V3 is a full-cover water block with an active backplate for the Leadtek NVIDIA RTX A6000 48GB PCIe and the listed NVIDIA server cards. It replaces the stock cooler and transfers heat from the GPU, memory, and power circuitry to the coolant in a custom liquid cooling loop.

Fits
Leadtek RTX A6000 / NVIDIA A40 / NVIDIA A10
Coverage
GPU, memory, and power circuitry
Backplate
Liquid-cooled

Compatibility

Fits only the PCB layouts listed below.

  • ✓Leadtek NVIDIA RTX A6000 48GB PCIe (Leadtek PCB)
  • ✓NVIDIA A40 48GB PCIe (NVIDIA A40 PCB)
  • ✓NVIDIA A10 24GB PCIe (NVIDIA A10 PCB)

Before ordering, confirm your exact card model and compare its PCB with the corresponding layout.

Leadtek RTX A6000 PCB layout.

Design Highlights

Contact surfaces for the GPU, memory, and power circuitry

Raised areas on the front cold plate line up with the components they cool. Thermal pads bridge the gap at the memory and power circuitry, while GPU thermal paste goes on the core.

Coolant flows through the backplate

The included backplate has a coolant channel on the back of the board.

Key Specifications

ModelN-RTXA6000-TC-V3
Cooling typeFull-cover GPU water block for a custom loop
Front block coverageGPU core, memory, and power circuitry
Rear coolingActive liquid-cooled backplate

Which Version Do I Need?

For a Leadtek RTX A6000, check for the A in RTX A6000. RTX 6000 Ada and RTX PRO 6000 Blackwell are different NVIDIA product names.

Bykski N-RTXA6000-TC-V3 Water BlockTHIS PAGE
Choose this block and backplate if you have a custom loop or want to choose the loop components yourself.
Choose the standard 360 mm kit for the same listed cards if you want the block, inline pump, and fan-cooled radiator already connected by tubing.

What's in the Box

Full-cover GPU water blockActive backplateMounting hardware

Thermal paste is not included (it cannot be shipped by air). Please use your own GPU thermal paste during installation.

Included active backplate.

Installation & Use

1
Power off the system, remove the graphics card, and take off its stock cooler.
2
Clean off the old thermal paste and pad residue. Check that the block aligns with the PCB mounting holes.
3
Use the specified pad thickness at each position. Place pads only where a component lines up with a raised contact surface on the block. A pad in the wrong spot can keep the block from sitting flush. Apply your own thermal paste only to the GPU core.
4
Align the block and backplate with the PCB. Tighten the mounting screws gradually and evenly.
5
Use fittings that match the ports and follow the inlet and outlet markings when you connect the tubing.
6
Fill the loop with coolant. With the rest of the system off, run only the pump and check the loop for leaks before powering the graphics card.

You also need a pump, reservoir or pump-and-reservoir combo, radiator, compatible fittings, tubing, and coolant.

FAQ

Are the NVIDIA A10 and A40 passively cooled from the factory?

Yes. Their stock heatsinks rely on system airflow. This block lets you connect either supported card to a custom liquid cooling loop.

Does this fit the 48GB RTX A6000?

Bykski lists the Leadtek NVIDIA RTX A6000 48GB PCIe with the Leadtek PCB. Compare your board layout before ordering.

Do I need a separate pump?

Yes. You need a pump to circulate coolant through the water block and radiator in your loop.

Does coolant pass through the backplate?

Yes. The active backplate has a coolant channel for rear-side cooling.

Notes
  • This is a repair or replacement-only item. Returns are not accepted on compatibility issues or if the block has had water/fluid run through it.
  • The product does NOT include printed instructions. The manufacturer reserves the right to alter the block design to expand compatibility. The delivered item may not 100% match the pictured item.
  • This product is designed for self-installation. The manufacturer is not liable for any damages resulting from misuse, including, but not limited to, improper installation or the use of incompatible hardware or fluids. By using this product, you accept all related risks.