Barrowch · FBFT08
See coolant temperature and flow at a glance
The Barrowch FBFT08 is an inline OLED flow meter and temperature sensor for a custom PC water cooling loop. Its G1/4 ports connect to the loop, and its screen shows coolant temperature and flow at the same time. Set a coolant temperature threshold to sound an alarm or trigger PC shutdown with the power-switch connection.
Power
12 V via motherboard FAN header
Protection
3 overheat modes
Fits / Use with
- ✓Custom PC water cooling loop with G1/4 male fittings.
- ✓Motherboard FAN header that can supply a steady 12 V.
- ✓Motherboard front-panel power-switch pins (PWR_SW) for automatic shutdown.
Choose fittings that fit your tubing and leave clearance for the ports, rear plug, and top buttons.
Design Highlights
Temperature and flow on one screen
Read coolant temperature in °C and flow in L/min without switching between screens.
Mode icons shown in order from 1 to 3.
Choose what happens when coolant overheats
When coolant passes your set temperature, the meter acts according to the mode you select.
- Mode 1 shuts down the PC automatically.
- Mode 2 sounds the buzzer.
- Mode 3 sounds the buzzer and shuts down the PC after 60 seconds.
Reverse the inlet to suit your tubing route
Facing the display, the factory inlet is on the right and the outlet is on the left. To swap sides, remove the end cap, reverse the impeller and round washer as shown, then reinstall the cap.
Key Specifications
| Model (SKU) | Barrowch FBFT08 |
|---|
| Coolant ports | 2 × G1/4 female |
|---|
| Housing | POM body and aluminum faceplate |
|---|
| Body (W × D × H) | 64 × 36 × 31.2 mm |
|---|
| Body weight | 78.1 g (black sample shown by Barrowch) |
|---|
| Display | 1.54-inch OLED |
|---|
| Readouts | Coolant temperature (°C) and flow (L/min) |
|---|
| Power input | Stable 12 V via motherboard FAN header at Full Speed |
|---|
| Overheat setpoint adjustment | 0–99 °C |
|---|
| Colors | Black (FBFT08_BK), white (FBFT08_WT) |
|---|
Manufacturer drawing. Dimensions in millimeters.
Which Version Do I Need?
Choose this model if you just need to see coolant temperature and flow.
Barrowch FBFT08THIS PAGE
Choose this model to set an overheat threshold and select a buzzer or PC shutdown mode.
What's in the Box
1 × FBFT08 OLED flow and temperature monitor set in the selected color
The optional external controller is sold separately.
Installation & Use
1Switch off the PC and drain the loop if it already contains coolant. Fit the monitor inline with G1/4 fittings and follow the selected inlet direction.
2Check the loop for leaks before powering the PC.
3With the FBFT08 disconnected, set the intended motherboard FAN header to Full Speed in BIOS for a steady 12 V. Shut down the PC. If you have the FBFT08 wiring harness, connect it to the monitor and the configured FAN header.
4For automatic shutdown, keep the PC off and use your motherboard manual to locate the PWR_SW pins. Connect the marked harness plug to those pins, then connect the case power-switch lead to the harness pass-through to keep the case button working.
5Power on the PC. From the main screen, press A once and use B to adjust the temperature threshold. Double-press A to open the mode menu, use B to choose a mode, then press A to save.
You’ll need G1/4 fittings matched to your loop tubing.
1 Monitor · 2 Motherboard FAN header · 3 Motherboard PWR_SW pins · 4 Case power-switch lead.
FAQ
How do I connect the FBFT08 for automatic shutdown?
You’ll need the FBFT08 wiring harness for this setup. With the monitor disconnected, set the FAN header to Full Speed in BIOS for a steady 12 V. Shut down the PC, connect the harness to the monitor, FAN header, and PWR_SW pins, then plug the case power-switch lead into the harness pass-through before powering on.
Can I feed coolant in from the left?
Yes. The factory setup is right in and left out when you face the screen. Reverse the internal impeller and round washer to make the left port the inlet.
Can I cancel a pending shutdown?
In Mode 3, press A during the 60-second delay to cancel shutdown. Set the warning temperature again after the protection mode triggers.
Does the 0–99 °C range refer to the alarm setting?
Yes. That is the adjustment range for the overheat threshold.
Notes- Avoid pressing hard on the OLED screen.
- In case of product appearance structure upgrade, without further notice, in kind prevail.