Bykski · N-ML5090GR-X
Full-cover water block for the Manli Gallardo RTX 5090D OC
The Bykski N-ML5090GR-X replaces the stock cooler on the Manli Gallardo GeForce RTX 5090D OC 32GB for use in a custom liquid cooling loop. Its T2 copper cold plate draws heat from the GPU core, memory, and voltage regulators. The bundle includes a black aluminum backplate and a 5V ARGB lighting controller.
Fits
Manli Gallardo RTX 5090D OC 32GB
Ports
G1/4 inlet and outlet
Compatibility
Bykski lists this graphics card for the N-ML5090GR-X.
- ✓Manli Gallardo GeForce RTX 5090D OC 32GB (Starship)
Check your card label for Manli model M-N509DGO/D732G-M3626. Before ordering, compare your PCB layout and mounting holes with the board shown in Bykski’s installation drawing below.
Manli’s product image of the card with its stock cooler.
Design Highlights
Bykski’s coolant-flow illustration.
Coolant path across the cold plate
Bykski specifies a 0.3 mm jet microchannel design with up to 56 channels.
5V addressable lighting
The clear window shows the coolant channels and the built-in ARGB lighting. Use the included controller if you prefer to run the lighting without motherboard sync.
Separate aluminum backplate
The backplate screws onto the rear of the graphics card PCB. The coolant connections are on the water block.
Key Specifications
| Model | N-ML5090GR-X |
|---|
| Coverage | GPU core, memory, and voltage regulators |
|---|
| Cold plate | T2 copper |
|---|
| Copper plate | 158.451 mm long × 6 mm thick |
|---|
| Copper under the channels | 0.35 mm at the point shown in Bykski’s cross section |
|---|
| Microchannels | 0.3 mm jet microchannel design, up to 56 channels |
|---|
| Channel surface area | 10,962.06 mm² |
|---|
| Backplate | Black aluminum |
|---|
| Water block (L × W × D) | 254.36 × 127.82 × 29.59 mm |
|---|
| Backplate (L × W × D) | 254.35 × 127.82 × 22.60 mm |
|---|
| Inlet and outlet thread | G1/4 |
|---|
| Lighting | 5V 3-pin ARGB (RBW), controller included |
|---|
Bykski’s dimension drawing. Water block above, backplate below. All measurements in millimeters.
Which Version Do I Need?
Check the exact model on your card label before choosing a Gallardo water block.
Bykski N-ML5090GR-XTHIS PAGE
Choose this ARGB block and controller bundle for the listed Manli Gallardo RTX 5090D OC 32GB PCB.
Compare this metal/POM block for the same 5090D Gallardo or for the Manli Gallardo RTX 5090 OC 32GB or ZOTAC GeForce RTX 5090D 32GB SOLID OC listed for the SR-V2.
What's in the Box
1 × full-cover GPU water block1 × black aluminum backplateThermal pad setMounting hardware set1 × 5V ARGB lighting controller2 × G1/4 stop plugs
Thermal paste is not included (it cannot be shipped by air). Please use your own thermal paste during installation.
① Water block · ② Thermal pads · ③ Your graphics card PCB · ④ Mounting screws · ⑤ Backplate · ⑥ Backplate screws.
Installation & Use
1Power down the PC, remove the graphics card, and detach the stock cooler. Clean the old thermal material from the contact surfaces.
2Cut the supplied thermal pads to fit and place them on the memory and power components shown in Bykski’s placement drawing. Apply your own thermal paste to the GPU die.
3Align the water block with the PCB mounting holes. Fasten the block and backplate as shown in the exploded drawing. If the holes do not line up, stop and recheck the PCB before tightening.
4Connect the inlet and outlet to your loop with G1/4 fittings that match your tubing. Seal any unused ports.
5Connect the lighting to the supplied controller or a compatible 5V 3-pin ARGB sync connection. Keep it away from 12V 4-pin RGB headers.
6Fill the loop and power only the pump for the leak test. Inspect every fitting for leaks before powering the graphics card.
For the loop, you’ll also need a pump, reservoir, radiator, radiator fans, G1/4 tubing fittings, tubing, and coolant.
Bykski’s placement drawing. The shaded regions around the GPU mark the memory and power components that take pads.
FAQ
Which RTX model is this water block for?
This version is for the Manli Gallardo GeForce RTX 5090D OC 32GB. Check the Manli model number and compare the PCB layout before ordering.
What fittings does the block use?
The inlet and outlet use G1/4 threads. Choose fittings that also match the type and size of your tubing.
Can I run the lighting without motherboard sync?
Yes. The included lighting controller can run the block’s 5V ARGB lighting on its own.
Where do the thermal pads go?
Place the supplied pads on the memory and power components marked in Bykski’s installation drawing.
Notes- This is a repair or replacement-only item. Returns are not accepted on compatibility issues or if the block has had water/fluid run through it.
- The manufacturer reserves the right to alter the block design to expand compatibility. The delivered item may not 100% match the pictured item.
- This product is designed for self-installation. The manufacturer is not liable for any damages resulting from misuse, including, but not limited to, improper installation or the use of incompatible hardware or fluids. By using this product, you accept all related risks.