Bykski · B-L2-4/6/8/10BM-X-V2
Run multiple GPU water blocks in parallel
This Bykski multi-port manifold routes coolant to several Bykski GPU water blocks in parallel within a custom liquid cooling loop. The black POM block brings the supply and return lines for each water block to one place, so you can route the tubing together in a multi-GPU workstation or server.
Fits
Bykski GPU water blocks
Fits / Use With
Bykski GPU water blocks in a custom loop
- ✓G1/4 water cooling fittings
Connect the manifold to the water blocks with tubing and fittings. Check each water block against its graphics card and measure the available space for the manifold and tubing.
Design Highlights
Manufacturer renderings of the 4-, 6-, 8-, and 10-channel versions.
Choose the number of branches
Choose a manifold with enough branches for the GPU water blocks in your loop. Check the space you’ll need for the block, fittings, and tubing bends.
Separate supply and return
Each water block connects to one port in each row. One row feeds coolant to the blocks and the other collects the return flow.
Key Specifications
| 4-channel model | B-L2-4BM-X-V2 |
|---|
| 6-channel model | B-L2-6BM-X-V2 |
|---|
| 8-channel model | B-L2-8BM-X-V2 |
|---|
| 10-channel model | B-L2-10BM-X-V2 |
|---|
| Body material | Black POM (polyoxymethylene) |
|---|
| Port thread | G1/4 |
|---|
| Flow layout | Parallel branches with common supply and return passages |
|---|
| 8-channel body length | 236.15 mm |
|---|
| 6-channel max. working pressure | 6 bar |
|---|
Manufacturer’s length drawing for the 8-channel version. Measurement in millimeters.
Which Version Do I Need?
Choose according to how you want to connect the GPU water blocks.
Bykski POM manifoldTHIS PAGE
Use this manifold to run tubing from individual GPU water blocks to a common supply and return.
Use this terminal to join two adjacent Bykski GPU water blocks directly. Check block fit and slot spacing on the listing.
What's in the Box
Bykski POM manifold in the selected channel configuration
Installation & Use
1Turn off and unplug the computer. Choose an orientation that gives you access to the manifold ports and room to route the tubing.
2Use G1/4 fittings to connect the loop’s main supply and return lines to separate passages in the manifold.
3Connect each GPU water block’s inlet and outlet to the corresponding supply and return rows. Seal unused ports with G1/4 stop plugs.
4Test the assembled loop for air leaks before powering on the computer. Bykski recommends a 24-hour test.
You’ll need GPU water blocks, a pump, a radiator, coolant, G1/4 fittings, tubing matched to those fittings, and stop plugs for any unused ports.
Manufacturer’s example of tubing routed to a vertically mounted manifold.
FAQ
What does 10-channel mean on this multi-port block?
The B-L2-10BM-X-V2 has ten pairs of branch ports. Each pair has a supply port and a return port for one GPU water block.
What fittings fit the manifold?
Use G1/4 fittings matched to the tubing in your loop.
Can I leave a branch unused?
Yes. Seal its unused ports with G1/4 stop plugs before you test the loop.
Does the manifold attach directly to a graphics card?
It connects to Bykski GPU water blocks through tubing and fittings. Select each GPU water block for the graphics card it will cool.
Notes- The GPU blocks and graphics cards in the detailed picture are only for reference and product function display.
- Installation should be performed by users familiar with custom liquid cooling systems. Bykski may update the product design without prior notice.
- This product is designed for self-installation.